- Transparent gateway
- Ethernet connection 10/100 BaseTX RJ45 with 20 sessions simultaneously
- Serial connection RS232/RS422/RS485 or MPI/PROFIBUS interface
- Power supply: 12-24VDC +/-20%
- Mounting on DIN rail
- 1 x digital input
- 1 x digital output
The Ewon500/Ewon4001 is an Ethernet gateway and has been designed for the network connection of your machines that have a Modbus protocol (RTU/TCP/IP). You can use the Ewon500/Ewon4001 to record and collect data via the network and visualize it on corresponding WEB pages. With up to 20 Ethernet sessions simultaneously, the Ewon500/Ewon4001 is unbeatable in its price class. As it is both a transparent and a programmable gateway, there are virtually no limits to the applications. With alarm management, you can easily define alarms and be notified of critical conditions by e-mail.
Transparent gateway
- ISOTCP/MPI
- MODBUS TCP / MODBUS RTU
- XIP / Unitelway
- EtherNet IP / DF1
Web interface and own websites
- Standard supports all PDA browsers
- SSI technology
- basic
- ASP
Integrated alarm management
- Limit values can be configured
- Notifications via email, SMS (via email), FTP and SNMP
Configuration
- Via web interface
- via FTP file upload
Typical applications
- PLC access via Ethernet
- Data access to: Schneider, Siemens, Allen-Bradley, Rockwell, etc.
- MES applications
- Ethernet connection of serial devices
- Local information management
- Alarm networks
Supported devices:
- each PLC/device with Ethernet TCP/IP
- each PLC/device with RS232/RS485
- Siemens S5: 90U, 95U, 100U, 110U, 115U, 135U
- Siemens S7: 200 series via PPI
- Siemens S7: 300 & 400 series via ISOTCP & MPI / PROFIBUS
- Siemens S7: 1200 series via ISOTCP
- Manufacturer-independent via MODBUS TCP & RTU
- Allen-Bradley SL500 & Logix family with DF1 & Ethernet IP
- Schneider TSX Premium & Micro with UNITELWAY & XIP
- Schneider Momentum, Quantum, Twido via MODBUS TCP/RTU
- Omron CJ and CS series via FINS TCP & FINS Hostlink
- Hitachi EH series via H-protocol & Ethernet H-protocol
- Mitsubishi Electric FX0 to FX3 series, Q series

Reliable operation and intelligent remote maintenance

Remote maintenance via the Internet and mobile communications

With Ewon, all parameters in a central location at a glance

is a universal tool for reading out and setting up Ewon routers, updating firmware, saving and restoring the configuration.
By downloading and using software and apps from this homepage, I agree to the terms and conditions and the supplementary software clause.

is used to connect your PC to your Ewon router via Talk2M using a VPN tunnel. This allows access from your PC to the network connected to your Ewon router as if you were connected locally. User and device management as well as insight into the connection report is also done via eCatcher.
By downloading and using software and apps from this website, I agree to the terms and conditions and the supplementary software clause.

enables a connection test to Talk2m from your PC. Various parameters are checked and you receive feedback.
By downloading and using software and apps from this website, I agree to the terms and conditions and the supplementary software clause.

emulates a serial interface (COM port) on your PC which is linked to the serial or MPI interface of the Ewon router. This allows you to access serial and MPI devices remotely.
By downloading and using software and apps from this homepage, I agree to the terms and conditions and the supplementary software clause.

Use this *.cfg file to import an Ewon router into your SIMATIC Manager. Suitable for Technical Note 0401 eWON.
By downloading and using software and apps from this homepage, I agree to the terms and conditions and the supplementary software clause.

Import this library into your TIA portal.
(Ewon Gateway station library for TIA V12)
Suitable for Technical Note 0401 eWON.
By downloading and using software and apps from this website, I agree to the terms and conditions and the supplementary software clause.

variables (tags) from a Siemens/VIPA controller
read out.
Status 03/2014

variables (tags) from a Rockwell Automation controller
read out.
Status 10/2010

Read variables (tags) via Modbus RTU and TCP.
Status 04/2011

Read variables (tags) from a Hitachi controller.
Status 10/2010

Read variables (tags) from a Mitsubishi control unit.
Status 05/2011

Read variables (tags) from an Omron controller.
Status 07/2011

Read variables (tags) from a Jetter controller.
Status 04/2013

Remote maintenance of a Siemens/VIPA control system
Status 10/2014

Remote maintenance of a Hitachi control system
Status 04/2011

Remote maintenance of an Omron controller
Status 03/2014

Remote maintenance of a Jetter controller
Status 04/2013

Remote maintenance of a Beckhoff controller
Status 03/2014


Technical Note Ewon 0301
variables (tags) from a Siemens/VIPA controller
read out.
Status 03/2014

Technical Note Ewon 0302
variables (tags) from a Rockwell Automation controller
read out.
Status 10/2010

Technical Note Ewon 0303
Read variables (tags) via Modbus RTU and TCP.
Status 04/2011

Technical Note Ewon 0304
Read variables (tags) from a Hitachi controller.
Status 10/2010

Technical Note Ewon 0305
Read variables (tags) from a Mitsubishi control unit.
Status 05/2011

Technical Note Ewon 0306
Read variables (tags) from an Omron controller.
Status 07/2011

Technical Note Ewon 0307
Read variables (tags) from a Jetter controller.
Status 04/2013

Technical Note Ewon 0401
Remote maintenance of a Siemens/VIPA control system
Status 10/2014

Technical Note Ewon 0404
Remote maintenance of a Hitachi control system
Status 04/2011

Technical Note Ewon 0408
Remote maintenance of a Beckhoff controller
Status 03/2014

Technical Note Ewon 0601
Establishing a VPN connection with Talk2M
Status 10/2017