HD67561-HD67562

Gateway Profibus DP Slave / Modbus RTU
HD67561-HD67562

Interfaces:
1x Profibus DP; 1x RS232, 1x RS485

DatasheetTechnical supportRequest/On-site presentation
  • Configurable gateway
  • Interface between Modbus RTU and Profibus DP
  • galvanic isolation
  • Reception and transmission of Modbus and Profibus data
  • High temperature range from -40 °C to +85 °C
Gateway Profibus DP Slave Modbus RTU HD67561 HD67562

The configurable gateway serial to Profibus DP enables communication between a Profibus DP network and a Modbus RTU network. The Modbus RTU participants can be addressed via the RS232 or RS485. The HD67561 gateway acts as a Modbus RTU master. The HD67562 gateway acts as a Modbus RTU slave. It can be easily configured via the RS232 interface using the associated PC software. Different transmission rates can be set, with a maximum transmission rate of 12 Mbps on the Profibus side. Installation is simple and reliable on a DIN rail.

Interfaces:

1x Profibus DP (Sub-D socket, 9-pin)
1x RS232 (Sub-D plug, 9-pin)
1x RS485 (removable screw terminal, 3-pin)

Data rate:

Profibus DP: Max. 12 Mbps
Serial: Max. 115 kbps

Galv. separation:

>2,000 VDC

LED:

2x signal display for supply and communication

Supply:

8 VDC to 35 VDC
8 VAC to 19 VAC, 50/60 Hz

Power consumption:

HD67561: 4 Watt/ VA
HD67562: 3.5 Watt/ VA

Software:

Free configuration software SW67561/SW67562 for parameterizing the
parameterization of the devices

Profibus GSD file:

You can generate the required Profibus GSD file with the free
free configuration software SW67561/SW67562.

Supported function codes:

HD67561: 01, 02, 03, 04, 05, 06, 15, 16
HD67562: 03, 04, 06, 16

Operating temperature:

-40°C to +85°C.

Humidity:

10% to 80% , non-condensing.

Housing:

Previous housing: PVC
New housing: PC-ABS

Dimensions (WxHxD):

Previous housing: 23 mm x 107 mm x 120 mm
New housing: 22.5 mm x 90.7 mm x 123 mm

Weight:

approx. 200 g

Fastening:

Mounting on the DIN rail.

Note:

The article description should always be viewed from the gateway's perspective.

Slaves can be connected to the HD67561 on the Modbus RTU side.

Masters can be connected to the HD67562 on the Modbus RTU side.

Customs tariff number:

8517 62 00

Manufacturer:

ADFweb.com S.r.l.

Broschüre Gateways 2025
Brochure / Safely connecting bus systems in industry & building management

Here you can download our Gateways brochure / Securely connecting bus systems in industry & building management.

Wachendorff Prozesstechnik
Electric mobility

Cost reduction thanks to gateways

Wachendorff Prozesstechnik
Elevator technology

Interference-free communication with gateways and repeaters

Anwendungsbericht Verfahrenstechnische Anlagen
Process engineering systems

Connect meters and volume correctors to the control room with gateways

Wachendorff Prozesstechnik
HD67561 - Gateway Profibus DP Slave to Modbus RTU Master

Wachendorff Prozesstechnik
HD67562 - Gateway Profibus DP Slave to Modbus RTU Slave

sw-HD67561
SW67561

Free configuration software SW67561 for
parameterization of the device.

By downloading and using software and apps from this website, I agree to the GTC and the supplementary software clause.

Wachendorff Prozesstechnik
SW67562

Free configuration software SW67562 for
parameterization of the device.

By downloading and using software and apps from this website, I agree to the GTC and the supplementary software clause.

Wachendorff Prozesstechnik
Technical Note 2401 Gateway

Integration of a device description file in the TIA portal
Version: 2.0

Technical Note Gateways
Technical Note 2201 Gateway commissioning

Technical Note Gateways
Technical Note 2102 Compositor project planning

copy / save / send

Technical Note Gateways
Technical Note 0302 Modbus

Modbus basics

Technical Note Gateways
Input bytes and output bytes

of a PLC with Profibus and Profinet gateways

FAQ
FREQUENTLY ASKED QUESTIONS
Netzgerät Hutschienen-Netzgerät DRS3-24
DRS3-24

DIN rail power supply unit DRS3-24

Single-phase input: 85 VAC to 264 VAC
Output: 24 VDC
Output power of 72 watts (3 A)
Operating temperature: -25 °C to +71 °C
Overload and overvoltage protection

Article no.Article descriptionAvailablePrice/ItemNumber
HD67561

Gateway Profibus DP Slave / Modbus RTU Master

on request
HD67562

Gateway Profibus DP Slave / Modbus RTU Slave

on request
AccessoriesAvailablePrice/ItemNumber
DRS4-24A

Power supply unit for DIN rail, 85 to 264 VAC, 24 VDC 4.2 A, screw terminal

on request
AC34107

Null modem cable, socket/socket, 3 m long

on request
= available from stock
= Delivery time approx. 1 week
= Please inquire about delivery time

Subject to prior sale

Prices exclude 19% VAT and shipping costs.