Gateway BACnet MS/TP Master / Profinet Slave
HD67719-MS/TP-XX
Interfaces:
1x Ethernet port, 1x RS485
- Read and write up to 512 BACnet objects
- Profibus data block size maximum 1,440 bytes
- Data exchange between BACnet and Profinet
- Galvanic 3-way isolation between BACnet / Profinet and power supply
- Transmission of project planning via Ethernet

Further information on this gateway is available on request. Please get in touch with the contact persons listed below.
Interfaces:
HD67719-MS/TP-A1:
1x Ethernet port (RJ45 socket)
1x RS485 (removable screw terminal, 3-pin)
HD67719-MS/TP-B2:
1x Ethernet port (RJ45 socket)
1x RS485 (screw terminal, 3-pin)
BACnet objects:
Read and write up to 512 BACnet objects
Profinet data block size:
Input block maximum 1,440 bytes
Output block maximum 1,440 bytes
LED:
4x signal display for supply and communication
Supply:
HD67719-MS/TP-A1:
12 VDC to 35 VDC or
8 VAC to 24 VAC, 50/60HZ
HD67719-MS/TP-B2:
12 VDC to 35 VDC or
8 VAC to 24 VAC, 50/60HZ
Power consumption:
HD67719-MS/TP-A1: 3.5 Watt / VA
HD67719-MS/TP-B2: 3.5 Watt / VA
Software:
Free configuration software SW67719 for
parameterization of the device.
BBMD functionality:
This gateway only supports BBMD in a rudimentary way. No "Registration by Foreign Devices" and no NAT.
Profinet XML file:
You can create the required Profinet XML file with the free
free configuration software SW67719.
Operating temperature:
-40 °C to +85 °C
Humidity:
10 % to 80 %, non-condensing
Housing:
Previous housing: PVC
New housing: PC-ABS
Dimensions (WxHxD):
HD67719-MS/TP-A1:
Previous housing: 23 mm x 107 mm x 120 mm
New housing: 22.5 mm x 90.7 mm x 123 mm
HD67719-MS/TP-B2:
71 mm x 95 mm x 60 mm
Weight:
approx. 200 g
Fastening:
Mounting on the DIN rail
Note:
The article description should always be viewed from the perspective of the gateway.
You can connect slaves to the HD67719 on the BACnet side and masters on the Profinet side.
Customs tariff number:
8517 62 00
Manufacturer:
ADFweb.com S.r.l.

Here you can download our Gateways brochure / Securely connecting bus systems in industry & building management.

Free configuration software SW67719 for
parameterization of the device.
By downloading and using software and apps from this website, I agree to the GTC and the supplementary software clause.

The "Protocol Implementation Conformance Statement" called "PICS" document describes the BACnet functionalities of a BACnet application.

DIN rail power supply unit DRS3-24
Single-phase input: 85 VAC to 264 VAC
Output: 24 VDC
Output power of 72 watts (3 A)
Operating temperature: -25 °C to +71 °C
Overload and overvoltage protection
DIN rail power supply AMR4-24
Single-phase input: 90 VAC to 264 VAC
Output: 24 VDC (2.5 A)
Operating temperature: -40 °C to +71 °C
Overload and overvoltage protection