FnIO module - CANopen fieldbus node NA9161
establishes the connection between the FnIO system and the Modbus RS232 fieldbus as a slave
Delisting
If you have any questions, please contact our technical application consultants.
- Direct diagnostics via LEDs on the fieldbus node
- Replacement of modules when wiring is still in place
- Manages expansion modules with 1, 2, 4, 8 and 16 channels
- Simple termination (no resistor or end module required)
- Free combination of digital and analog I/O and special functions

As a slave, the NA9161 fieldbus node establishes the connection between the
the FnIO system and the CANopen fieldbus.
The I/O modules used are automatically recognized and the fieldbus node
fieldbus node creates a local process image. The sequence of the
analog extension modules (data exchange word by word) and digital
(data exchange bit by bit) is arbitrary and can be mixed.
can be mixed. The internal process image of the fieldbus node
NA9161 is stored in the memory of the relevant controller via the CANopen field bus.
responsible controller via the CANopen field bus. By dividing the
process image into an input and output data area, the process data is
the process data is read in via the CANopen bus, processed further in a
controller and the process output data is output via the CANopen bus.
CANopen bus.
The automatically generated process image is created in the order of the
expansion modules in their slots.
If the number of digital I/Os exceeds 8 bits, a
byte is started by the fieldbus node.
Power supply:
Supply voltage: 24 VDC typical
Supply voltage range: 11 VDC to 28.8 VDC
Power consumption:
100 mA typical at 24 VDC
Current consumption of the I/O module:
max. 1.5 A at 5 V
Isolation:
Network to logic: isolated
Logic to field voltage: isolated
Logic to system voltage: not isolated
Max. Field power Contact:
max. 10 ADC
Module dimensions (LxHxW):
45 mm x 99 mm x 70 mm
Weight:
155 g
Operating temperature:
0 °C to 55 °C
Storage temperature:
-25 °C to +85 °C
Sync-Modbus:
Supports
Auto baud rate:
Supports
Fail-safe mode:
Supports
Bus subscriber type:
Slave
FMS support:
not supported
Baud rate:
1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200
baud

in combination with a Wachendorff control unit and a Wachendorff CANopen fledbus node (NA9161)

in combination with a Wachendorff operating device, a Wachendorff CANopen Fledbus node (NA9161) and 1-channel SSI module ST5351