Advanced strain gauge signal converter WZ-SG2
1 output optional: 0/4 mA to 20 mA, 0 V to 5/10 V, 1 digital output
- Scalable input for 4- or 6-wire strain gages
- Programming via Micro-USB data cable
- Taring input and serial RS485 interface
- Configurable sampling rate, resolution and alarm threshold
- Counting function
- Automatic tare function
- Recording of minimum and maximum net weights
- Data logging function
- Quick and safe adjustment
- High fire safety thanks to the flame-retardant fiberglass/nylon housing
- 3-way insulation ( power supply / signal input / signal output ) up to 1500 VAC

In addition to converting the input signal into a scalable standard signal, the microprocessor-controlled transducer for strain gages WZSG also offers the option of a taring function or an output for outputting when a threshold value is reached. The Advances variant has the option of configuring the resolution and sampling rate, as well as defining any alarm threshold. This version also has a counting function, the recording of minimum and maximum net weights, an automatic taring function and a data logging function (free additional software EASY Setup). The output signal can be provided as an analog current or voltage signal. The WZSG module also converts the input signals into a MODBUS RTU protocol. The data can be made available to corresponding evaluation devices via an RS485 interface. This means that the use of a controller is not necessary. The device is fully set up using the programming cable and simple software and is immediately ready for operation. The WZSG is simply snapped onto a DIN rail for installation.
Inputs:
1x strain gauge measuring bridge with 1 to 4 load cells (350 Ohm) or 1 to 8 load cells (1,000 kOhm); 4 or 6-wire differential input, minimum connection resistance 87 Ω
1x digital input
Outputs:
1 output optional:
0/4 mA to 20 mA
0 V to 5/10 V
1 digital output
Advanced functions:
Resolution configurable
Sampling rate adjustable from 5.4 Hz to 1365.3 Hz
Alarm threshold adjustable
Measurement stabilized by noise filter
Measurements available in integer and floating point
Counting function
Recording of min/max net weight values
Automatic reset / tare
Protocol:
Modbus RTU slave
Baud rate:
2,400 bps to 115,200 bps
Sampling rate:
Measuring bridge: 12.53 Hz to 151.71 Hz
Resolution:
24 bit
Accuracy:
0.01 % Calibration
0.01 % Linearity
0.0025 % / ° C Temperature coefficient
Analog output: 0.1 % of span.
Settings:
Bus termination via DIP switch,
Parameterization via configurable software
Cable length:
max. 1,200 m
Isolation:
Galvanic isolation: 1,500 VAC
Supply:
10 VDC to 40 VDC, max. 2 W
19 VAC to 28 VAC, 50/ 60 Hz
Ambient conditions:
Working temperature: -10° C to +65° C
Storage temperature: - 20° C to +85° C
30 % to 90 % relative humidity at 40 °C
Safety:
EN61010-1:2013-10
EMC:
EN61000-6-2:2006-10
EN61000-4-4:2013-01
EN61000-6-4:2007-11 + A1:2013-01
EN61000-4-5:2015-05
EN61000-4-2:2011-04
EN61000-4-6:2014-09
EN61000-4-3:2007-04 + A1:2009-01 + A2:2011-01
EN61000-4-11:2006-02
MTBF:
486 years at 35°C ambient temperature
Housing:
Sturdy PBT plastic housing
Protection class:
IP20
Dimensions (WxHxD):
17.5 mm x 100 mm x 112 mm
Connections/mounting:
Pluggable and coded screw terminals up to 2.5 mm2
IDC10 connection for WZ-Bus system on 35 mm DIN rail
more on request...
Weight:
approx. 120 g
Scope of delivery:
Device, installation instructions
Manufacturer:
Seneca s.r.l.

You can download the handout Signal converter here.

Configuration software for signal converters.
By downloading and using software and apps from this website, I agree to the GTC and the supplementary software clause.