Gateway CANopen / Modbus TCP Client
HD67504-XX
Interfaces:
1x CANopen
1x Ethernet
- Configurable gateway with SW67504
- Bidirectional data exchange between CANopen and Modbus TCP
- Galvanic 3-way isolation between CANopen / Ethernet and power supply
- High temperature range from -40 °C to +85 °C
- Transmission of project planning via Ethernet

The configurable gateway HD67504-XX enables communication between a Modbus TCP server and a CANopen network. The gateway can be used as a data converter with an adjustable translation table. As a Modbus TCP client, the gateway can receive data from several participants and make it available to a higher-level system. Of course, data can also be transmitted in the opposite direction. The HD67504-XX can send messages independently in the Modbus TCP network. Transferring the configuration of the gateway using the SW67504 software via the Ethernet port is very quick and easy. The top-hat rail mounting and removable screw terminals (HD67504-A1) ensure quick and safe installation and easy wiring of the device.
Interfaces:
HD67504-A1:
1x Ethernet port (RJ45 socket)
1x CANopen (removable screw terminal, 3-pin)
HD67504-B2:
1x Ethernet port (RJ45 socket)
1x CANopen (screw terminal, 3-pin)
Data rate CANopen:
Max. 1 Mbps
LED:
HD67504-A1:
4x signal display for supply and communication
HD67504-B2:
5x signal display for supply and communication
Supply:
HD67504-A1:
12 to 35 VDC, 3.5 Watt or
8 to 24 VAC, 3.5 VA, 50/60 Hz
HD67504-B2:
12 to 35 VDC, 3.5 Watt or
8 to 24 VAC, 3.5 VA, 50/60 Hz
Power consumption
3.5 Watt / VA
Software:
Free configuration software SW67504 for
parameterization of the device
Supported function codes:
01, 02, 03, 04, 05, 06, 15
Operating temperature:
-40 °C to 85 °C
Humidity:
10% to 80%, non-condensing
Housing:
Previous housing: PVC
New housing: PC-ABS
Dimensions (WxHxD):
HD67504-A1:
Previous housing: 23 mm x 107 mm x 120 mm
New housing: 22.5 mm x 90.7 mm x 123 mm
HD67504-B2:
71 mm x 95 mm x 60 mm
Weight:
approx. 200 g
Fastening:
Mounting on DIN rail
Note:
The item description should always be viewed from the perspective of the gateway.
Servers (slaves) can be connected to the HD67504-XX on the Modbus TCP side.
Customs tariff number:
8517 62 00
Manufacturer:
ADFweb.com S.r.l.

Here you can download our Gateways brochure / Securely connecting bus systems in industry & building management.

Free configuration software SW67504 for
parameterization of the device.
By downloading and using software and apps from this website, I agree to the GTC and the supplementary software clause.

DIN rail power supply unit DRS3-24
Single-phase input: 85 VAC to 264 VAC
Output: 24 VDC
Output power of 72 watts (3 A)
Operating temperature: -25 °C to +71 °C
Overload and overvoltage protection
DIN rail power supply AMR4-24
Single-phase input: 90 VAC to 264 VAC
Output: 24 VDC (2.5 A)
Operating temperature: -40 °C to +71 °C