DCMPUL101 compact data logger for pulses
has been discontinued without replacement as of 01.08.2015.
1 measurement input for pulses up to 10 kHz
Memory capacity for a total of 500,000 measurements
- 1 measurement input for pulses up to 10 kHz
- Memory capacity for a total of 500,000 measurements
- Programmable scaling factor, offset and unit
- Easily programmable via software
- Simple export of measurement data to EXCEL™
- Battery operation with a service life of up to 10 years

The DCMPUL101 data logger is an inexpensive battery-operated
small data logger with a very large memory capacity, very long battery
battery life, start/stop function and much more. It can be
very easily via self-explanatory software for the automatic recording of pulse
recording of pulse signals. The
pulses per time unit are counted and recorded. A typical
typical area of application is, for example, the recording of flow measurements.
Due to the flexible setting of the scaling, the offset
offset and the physical unit, the compact data loggers can be adapted
can be adapted to almost all sensors with pulse output.
Measuring channel:
1 measuring channel for pulse signals
Entrance area:
TTL signals, pulse signals 0 VDC to +30 VDC or
potential-free contacts, maximum input frequency 10 kHz; input impedance:
>60 kOhm. Minimum pulse width active input:
High >2.8 VDC, Low < 0.4 VDC
Storage:
500,000 measurements maximum. Ring memory mode
adjustable via software.
250,000 measurements in start/stop mode (multiple start and stop of storage).
stopping the storage).
Recording rate:
1 measurement/second to 1 measurement/24 hours.
Physical unit:
Each physical unit with up to 10
characters is programmable via software and is stored in the device.
stored in the device.
Real-time viewing:
The data logger can be used in conjunction with a
PC for direct viewing and storage of the measurement data.
can be used.
Interface:
USB interface (interface interface required);
115,200 baud.
Operating display:
Two LEDs on the front panel to display the recording
recording status, battery status, alarm and memory status.
Supply:
Replaceable 3.6 V lithium battery (included) with a typical service life of
typical service life of 10 years at 25 °C (depending on frequency and
frequency and cycle time of the pulse).
Time accuracy:
+/-1 minute per month at 20 °C operating temperature,
when the interface is not in operation.
Data format:
The data is provided with the date and time as well as the
physical unit programmed via software.
Ambient temperature:
-40 °C to +80 °C, 0 % to 95 % relative humidity.
humidity.
Sensor connection:
Via plug-in screw terminals.
The data logger can only be used with the DCMIFC200 interface cable (USB)

Project planning software for compact data loggers.
For device parameterization, data evaluation and data storage.