Gateway Profinet Slave / Modbus TCP Client (Master)
HD67611-A1
Interfaces:
1x Profinet-capable port, 1x Modbus TCP-capable port
- Integrated switch
- Configurable gateway for free data management
- High temperature range from -40 °C to +85 °C
- Galvanic isolation
- Profinet data block size maximum 1,440 bytes

The configurable gateway HD67611-A1 enables communication between a Modbus TCP server (slave) and a PROFINET master. The top-hat rail mounting and plug-in screw terminals ensure quick and safe installation and easy wiring of the device. Using the free SW67611 project planning software, the Modbus TCP registers are assigned to the PROFINET side byte by byte for bidirectional data exchange and vice versa. At the end of your project planning, you generate an XML device description file that you simply integrate into your PROFINET project planning. The configuration is transferred via Ethernet.
Interfaces:
2x Ethernet port (RJ45 socket) for Profinet and Modbus-TCP
No physical network separation!
Note: The switch function between the Ethernet ports allows separate networks to be topologically connected.
Profinet data block size:
Input block size maximum 1,440 bytes
Output block size maximum 1,440 bytes
LED:
6x signal display for supply and communication
Supply:
12 VDC to 35 VDC or 8 VAC to 24 VAC
Power consumption:
HD67611-A1: 3.5 Watt/VA
Software:
Free configuration software SW67611 for
parameterization of the device.
Profinet XML file:
You can create the required Profinet XML file with the free
free configuration software SW67611.
Supported function codes:
01, 02, 03, 04, 05, 06, 15, 16
Operating temperature:
-40 °C to +85 °C.
Humidity:
10 % to 80 % , non-condensing.
Housing:
Previous housing: PVC
New housing: PC-ABS
Dimensions (WxHxD):
Previous housing: 23 mm x 107 mm x 120 mm
New housing: 22.5 mm x 90.7 mm x 123 mm
Weight:
approx. 200 g
Fastening:
Mounting on the DIN top-hat rail.
Note:
The article description should always be viewed from the perspective of the gateway.
You can connect masters to the HD67611 on the Profinet side and servers (slaves) on the Modbus TCP side.
Customs tariff number:
8517 62 00
Manufacturer:
ADFweb.com S.r.l.

Free configuration software SW67611 for
parameterization of the device.
By downloading and using software and apps from this website, I agree to the GTC and the supplementary software clause.

Here you can download our Gateways brochure / Securely connecting bus systems in industry & building management.

Integration of a device description file in the TIA portal

DIN rail power supply unit DRS3-24
Single-phase input: 85 VAC to 264 VAC
Output: 24 VDC
Output power of 72 watts (3 A)
Operating temperature: -25 °C to +71 °C
Overload and overvoltage protection