Three-axis shock, temperature, pressure and humidity data logger
has been discontinued without replacement as of 01.08.2015.
6-channel compact data logger with additional temperature, humidity and pressure sensors
115,200 baud
- Weight:
- Total of 174,762 measurements / channel
- Programmable scaling factor, offset and unit
- Easily programmable via software
- Simple export of measurement data to Microsoft EXCEL®
- Real-time operation

The DCMUSHEBx is a battery-operated, high-resolution data logger.
data logger. It can be set up very easily using self-explanatory software
for recording shock, temperature, pressure and humidity.
can be programmed.
Due to the flexible setting and the robust housing, the
data logger is particularly suitable for monitoring the transportation of valuable goods
and machines. The measured values are stored in a
non-volatile memory and are available even after a battery
available even after a battery failure. The housing consists of a compact
compact aluminum block and is therefore also suitable for harsh
industrial use.
Channel: Temperature (°C)
Measuring range: -20 °C to +54 °C
Resolution: 0.1 °C
Accuracy: ±0.5 °C
Channel: Humidity (rH)
Measuring range: 0% to 95
Resolution: 0.1 °C
Accuracy: ±3 % RH
Channel: Pressure (PSIA)
Measuring range: 0 PSIA to 30 PSIA
Resolution: 0.002 PSIA
Accuracy: ±1 % of the measuring range
Measuring range shock: ±5 g
Resolution (g): 0.01 g
Accuracy (g): ±0,2 g
Measuring range shock: ±50 g
Resolution (g): 0.05 g
Accuracy (g): ±1,0 g
Measuring range shock: ±100 g
Resolution (g): 0.1 g
Accuracy (g): ±2,0 g
Measuring range shock: ±250 g
Resolution (g): 0.2 g
Accuracy (g): ±4,0 g
Storage:
174,762 measurements per channel maximum.
Recording rate:
Adjustable from 64 times per second to
once every 5 minutes for shock. Minimum rate for temperature,
pressure and humidity 2 seconds, maximum rate every 5 minutes.
Measuring rate shock:
1.953 ms (512 Hz)
Real-time viewing:
The data logger can be used in conjunction with a
PC for direct viewing and storage of the measurement data.
can be used.
Interface:
USB interface (interface cable required);
115,200 baud.
Power supply:
6 replaceable 1.5 V mono (type D) alkaline batteries with a typical runtime of 60 days at a measuring rate of one minute at 25 °C.
Time accuracy:
±1 minute per month at 2 °C to 30 °C
Operating temperature when the USB interface is not in operation.
The data logger can only be used with the DCMIFC200 interface cable (USB)

Project planning software for compact data loggers.
For device parameterization, data evaluation and data storage.
By downloading and using software and apps from this website, I agree to the GTC and the supplementary software clause.