T48

PID temperature controller T48

4-digit digital display for temperature measurement via thermocouples or Pt100
3 outputs either relay or solid state relay

Product discontinuation as of 01.07.2018

DatasheetTechnical supportRequest/On-site presentation
  • PID temperature controller in 48 x 48 mm format
  • Temperature detection via thermocouples or PT100
  • 3 outputs optionally relay or solid state relay - driver for 1 - 2 control outputs and 1 - 2 alarm outputs, triac
  • Option: analog output, 2nd analog input
  • Output board can be easily replaced from the front
  • Extremely simple programming and operation
  • IP 65 protection class for harsh industrial environments
  • Programming on the device or optionally with Windows software

Product discontinuation:
The temperature controllers, of the T48 series, have been discontinued as of 01.07.2018. Therefore, only the devices listed below are still available. If the device you are looking for is not available, please contact our application consultants
. We will be happy to advise you on alternatives.

This small temperature controller is an all-rounder. Equipped with a newly developed Thermo-ASIC, modern programming, operating and control technologies are implemented in a housing designed for harsh industrial use. Everything has been done to ensure that the T48 is quick to commission, easy and safe to operate and performs its task efficiently for many years. Finally, superior functionality ensures simple adaptation to all conceivable control tasks. The process parameters can be determined via self-optimization and then easily modified. The operator is continuously informed of the actual value. The second display allows the setpoint, percentage output or deviation to be displayed at the touch of a button. The T48 has a newly developed calculation algorithm, with which the target value is approached particularly quickly and overshoot is minimized. The output board can be changed quickly and easily.

Display

Actual value: 4-digit, 10 mm high red LED.
Information: 4-digit, 8 mm high green LED for setpoint, % output power, deviation, unit °F or °C.

Important data

Indicators: 6 LEDs provide information about important statuses
Input: Signal input: Adjustable for thermocouples type S,T,J,N,K,E,R,B. or Pt100 (2 or 3 wire), -5 to 56 mV or 1.0 to 320.0 Ohm.
Measuring cycle: 100 ms.
Response time: typ. 300 ms, max. 400 ms.
User input: Alternatively adjustable functions: Program lock, lock integral component, switch automatic/manual mode, end start-up ramp, reset alarms.
Degree of protection: Water jet-proof and dust-proof from the front in accordance with IP 65.

User input

Alternatively adjustable functions: Program lock, lock integral part, switch automatic/manual mode, end start-up ramp, reset alarms.

Power supply

AC version: 85 - 250 VAC, 50/60 Hz, 8 VA.
DC version: DC: 18 - 36 VDC, 7 W; AC: 24 VAC, 50/60 Hz, 9VA.

Housing

Flame- and scratch-resistant black plastic.
Rear panel is mounted on the control panel, front panel can be pulled out. Devices can be mounted directly next to each other.
Dimensions: W 50 x H 50 x D 106 mm. Panel cut-out DIN W 45 x H 45 mm. Mounting via mounting frame with clamping screws.
Ambient temperature: Operation: 0°...+50°C, storage: -40° to +80°C.

Accessories

Solid-state relay: Is connected to the SSR driver output and switches 50 to 280 VAC (nominal 240 VAC) at max. 45 A (35 A at ambient temperature = 50 °C).
Dimensions: W 140 x H 120 x D 66 mm (incl. heat sink).
Spare boards: Spare output boards equipped with 1 or 3 relays/SSRs. The basic version includes a control output for two-point control with P, I, PI, PD and PID behavior. The output is time-proportional.

Outputs

Relay output: NO contact, 3 A at 250 VAC or 30 VDC (resistive load).
75 VA at 120 VAC (inductive load).
SSR driver output: 45 mA at min. 4 V nominal 7 V.
Alarm outputs: 1 or 2 NO contacts with common ground, 3 A at 250 VAC or 30 VDC (resistive load) 75 VA at 120 VAC (inductive load).
Second control output (cooling): programmable instead of the 2nd alarm output: with P, I, PI, PD and PID behavior.
Analog output: freely scalable, 0 - 20 mA, 4 - 20 mA or 0 to 10 V with a resolution of 3500 steps.
Second analog output: refers directly to the input signal.
Heating current monitoring: 100 mA AC from e.g. current transformer (see accessories), 50 - 460 Hz, galvanically isolated.
Serial interface: RS485, 32 devices can be networked, max. baud rate: 9600.
2nd analog input, setpoint specification: 0/4 - 20 mA, freely scalable, for external setpoint specification or cascade control with 2 control loops.

Datenblatt
Data sheet T48

info Flyer Einbaumessgeräte
Advertising brochure built-in measuring devices

Rules, displays and monitoring

Wachendorff Prozesstechnik
Crimson 2.1

Project planning software for CUB5 series, LD series, PAX and PAX2 series, PXU series, T/P16 series, T/P48 series, TCU series and ICM8.

By downloading and using software and apps from this website, I agree to the GTC and the supplementary software clause.

Anwendungsbericht Wachendorff Prozesstechnik
Laboratories: Automation with digital displays

Bog body and temperature regulator

URDRxxxx

DIN rail adapter for devices in the
UR3274 series
UR4848 series
OLED displays