Industry - Temperature display PAXT
5-digit digital display
20 measurements/sec., thermocouples, Pt100 and Ohm,
serial interface: Profibus-DP, RS232, RS485
- 5-digit, 14 mm high LED, indicators, backlit unit
- Display readable in sunlight
- 20 measurements/sec, thermocouples, Pt 100 and Ohm 0-10 V, serial interface: PROFIBUS-DP, RS232, RS485,
- Easy programming on the device or via PC
- summation, min/max value, 16-step linearization
- High degree of protection IP 65, dimensions: 48 x 96 x 104 mm

The PAX T industrial temperature indicator can of course also be used as a very flexible and accurate laboratory device. However, with its robust plastic housing and high IP 65 protection rating, it has been designed for harsh industrial use. The device is configured quickly and safely either via the PC or directly using 5 keys. The operator is pleased with the clear user interface with which he can easily record all parameters at a glance and easily change values. Devices can also be retrofitted using the plug-in options.
Inputs:
The following sensors are accepted:
Thermocouples:
Type S, T, J, N, K, E, R, B, N, C
Pt100 sensors:
3 wire, 2 wire can be compensated,
Power supply: 100 Ohm range: 165 µA, 10 Ohm range: 2.6 mA
100 Ohm PT a = 0.00385, 100 Ohm PT a = 0.003919, 120 Ohm nickel,
10 Ohm copper a = 0.00427
mV or Ohm:
16 linearization points, scaling via programming or actual value transfer.
Display range: -19999 to 99999.
-10,000...+65,000 mV, 0...400,00 Ohm , 0...25,00 Ohm
For accuracy tables see drawings.
Display:
5-digit, 14 mm high red LED. Dimmable via keypad or user inputs.
Buttons:
The device is programmed and operated using the 5 push buttons on the front.
Housing:
Dark red, impact-resistant plastic housing. The electronic slide-in unit can be pulled out from the rear. One unit can be inserted. The plug-in cards can be installed very easily.
Supply:
PAXT0000: 85 VAC to 250 VAC
PAXT0010: 11 VDC to 36 VDC / 24 VAC
Backlit unit:
A physical unit can easily be attached behind the display. With the label sheet, which contains all the usual units, the user can easily realize his desired unit backlit. Unit "°C" or "°F" is supplied.
User input:
3 programmable inputs are available. They can be set to PNP or NPN switching via jumpers.
Totalizer:
The totalizer can create a product from the input signal and time. It can either totalize automatically over a time or with a user input. A time base and a factor make the unit flexible. It has 9 digits and it is possible to change between the first 4 and the second 5 digits. The accuracy of the time base is typically 0.01 %.
Indicators:
MAX Maximum value is displayed
MIN Minimum value is displayed
TOT Total is displayed, flashes on overflow
SP1 Output 1 is active
SP2 Output 2 is active
SP3 Output 3 is active
SP4 Output 4 is active
Panel cut-out according to DIN:
92 mm x 45 mm. Fastening via mounting frame with clamping screws.
Measuring rate:
20 measurements/second. A/D converter with 16 bit resolution.
Response times:
200 ms for display of 99 % of the final value, max. 700 ms (increases with increase in digital filtering).
Dimensions:
W 97 mm x H 50 mm x D 104 mm.
Panel cut-out according to DIN: 92 mm x 45 mm.
Protection class:
Jet-proof and dust-tight to IP 65 from the front.
Power supply:
PAXT000 0/B: 85 to 250 VAC 50/60 Hz, 15 VA.
PAXT001 0/B: 11 to 36 VDC, 11 W or 24 VAC +/-10 %, 15 VA.
Relative humidity:
max. 85 %. rH, non-condensing.
Ambient temperature:
Operation: 0 °C to +50 °C.
With all 3 cards fitted: 0 °C to 45 °C.
Storage: -40 °C to +60 °C
Programming:
Programming is possible if the programming lock input is not activated. All the necessary parameters can then be set using the 5 front buttons
Programming with PC software:
With the Crimson 2 Windows software, all project data can be easily created, managed, copied, registered and transferred to the PAX on the PC. A starter package consisting of software, RS232 interface and PC/PAX cable makes it easy to decide in favor of this programming.
Approvals:
UL approval (Underwriters Laboratories) for the USA and Canada
Fastening
via mounting frame with clamping screws.
Scope of delivery:
Device, fixing material, seal, operating instructions.
Weight:
approx. 300 g (without plug-in options).
Output cards:
The device can be very easily upgraded with different output cards. Each device can be equipped with a maximum of one interface card, one relay or transistor output card and one analog output card. You can easily install the cards yourself.
Customs tariff number:
9032 89 00
Manufacturer:
Red Lion Controls, USA.
Pluggable interface card:
1. half-duplex RS232, programmable
2. multipoint RS485, programmable
3. DeviceNet, programmable
4. PROFIBUS-DP, programmable
5. ModBus, programmable (via RS485 or RS232 interface)
Pluggable relay output cards:
1. 2x relay changeover contact 5 A at 120/240 VAC or 28 VDC (ohmic load), at 120 VAC (90 VA inductive load). Service life of the relays is 100,000 cycles at max. load. The service life increases with lower loads.
2. 4x NO relay 3 A at 240 VAC or 30 VDC (resistive load), at 120 VAC (70 VA inductive load). The service life of the relays is 100,000 cycles at max. load. The service life increases with lower loads.
Pluggable transistor output cards:
1. 4x NPN-OC transistors: max. 100mA at Vsat = 0.7 V, Vmax 30 V, galvanic isolation of 500 V against the signal input.
2. 4x PNP-OC transistors: Internal supply: 24 VDC +/-10 %, max. 30 mA all 4 transistors. External supply: max. 30 VDC, 100 mA for each individual transistor.
Pluggable analog output card:
Selectable output signal: 0 to 20 mA, 4 to 20 mA, 0 to 10 VDC. Digitally scalable, offset.
Accuracy: 0.17 % of range at 18 °C to 28 °C operating temperature;
0.4 % of range at 0 °C to 50 °C operating temperature.
Resolution: 1/3,500
Load: 0 VDC to 10 VDC at min. 10 kOhm;
0/4 to 20 mA at max. 500 Ohm.
Galvanically isolated from the signal input up to 500 V.
Programming on the device:
Programming is possible if the programming lock input is not activated. All the necessary parameters can then be set using the 5 front buttons. This possibility of quick project planning is one of the main advantages of all PAX devices.
Programming with PC software:
With the free Windows software Crimson 2, all project data can be easily created, managed, copied and transferred to the PAX device on the PC. Every user who frequently uses PAX devices can save the individual projects here and use existing knowledge for similar tasks. A starter package consisting of software, USB interface card and PC/PAX connection cable makes it easy to decide in favor of this programming.

Project planning software for CUB5 series, LD series, PAX and PAX2 series, PXU series, T/P16 series, T/P48 series, TCU series and ICM8.
By downloading and using software and apps from this website, I agree to the GTC and the supplementary software clause.

How photovoltaics becomes economical

Price-efficient digital displays for mass flow measurement

Digital displays in the tensile force measurement

Filter monitoring via two separate channels - flexible and accurate