Status data logger DCMSTA101
has been discontinued without replacement as of 01.08.2015.
1-channel compact data logger for status recording
2,400 baud or 57,600 baud
- Measuring range 0 VDC to 12 VDC measurements
- Memory: For 406,232 measured values
- Input resistance: >1 KOhm
- Signal level: Low < 0.4 V / High > 2.8 V
- Scaling: Freely scalable
- Ambient conditions: -40 °C to +80 °C; 0 % rH to 95 % rH

The DCMSTA compact data logger is a battery-operated small
data logger for the measurement of status signals ( High / Low ), with a max.
a max. resolution of 4 Hz (250 ms). This can be set via the software
adjustable via the software. The use of a recording system that only records
status changes guarantees a long recording phase.
recording phase. The non-volatile internal memory ensures
high data security, even if the battery is exhausted.
The data logger can be easily set, started and stopped via the PC.
stopped by the PC. In addition, the data logger can be started/stopped
can be started/stopped by pushbutton. The comprehensive and user-friendly
software automatically recognizes the connected data logger and
allows easy evaluation of the measurement data.
DCMSTA101
- Battery: replaceable 3.6 V lithium
- Battery life: typical life at +25 °C, 10 years
- Measuring rate: Adjustable from 4 measurements per second to
to 1 measurement every 24 hours.
- Interface speed: 2,400 baud
- Housing: ABS plastic
- Dimensions (W x H x D): 36 x 56 x 16 mm
- Weight: 24 g
- On and off times can be set via the software and activated via the Start7Stop pushbutton
The data logger can only be used with the DCMIFC200 interface cable (USB)

Project planning software for compact data loggers.
For device parameterization, data evaluation and data storage.
By downloading and using software and apps from this website, I agree to the GTC and the supplementary software clause.