WZ-SG

Strain gauge signal converter WZ-SG

1 output optional: 0/4 mA to 20 mA, 0 V to 5/10 V, 1 digital output

DatasheetTechnical support
  • Scalable input for 4- or 6-wire strain gages
  • Taring input and RS485 serial interface
  • Fast and safe adjustment
  • High fire safety due to the flame-retardant fiberglass-nylon housing
  • 3-way isolation ( power supply / signal input / signal output ) up to 1500 VAC
Signalewandler WZSG

In addition to converting the input signal into a scalable standard signal, the WZSG microprocessor-controlled transducer for strain gages also offers the option of a taring function or an output for outputting when a threshold value is reached. The output signal can be output as an analog current or voltage signal. The WZSG module also converts the input signals into a MODBUS RTU protocol. The data can be made available to corresponding evaluation devices via an RS485 interface. This means that the use of a controller is not necessary. The device is fully set up using the programming cable and simple software and is immediately ready for operation. The WZSG is simply snapped onto a top-hat rail for installation.

Inputs:

1x strain gauge measuring bridge with 1 to 4 load cells (350 Ohm) or 1 to 8 load cells (1,000 kOhm); 4 or 6-wire differential input, minimum connection resistance 87 Ω
1x digital input

Outputs:

1 output optional:
0/4 mA to 20 mA
0 V to 5/10 V
1 digital output

Protocol:

Modbus RTU slave

Baud rate:

2,400 bps to 115,200 bps

Sampling rate:

Measuring bridge: 12.53 Hz to 151.71 Hz

Resolution:

24 bit

Accuracy:

0.01 % Calibration
0.01 % Linearity
0.0025 % / ° C Temperature coefficient
Analog output: 0.1 % of span.

Settings:

Bus termination via DIP switch,
Parameterization via configurable software

Cable length:

max. 1,200 m

Isolation:

Galvanic isolation: 1,500 VAC

Supply:

10 VDC to 40 VDC, max. 2 W
19 VAC to 28 VAC, 50/ 60 Hz

Ambient conditions:

Working temperature: -10° C to +65° C
Storage temperature: - 20° C to +85° C
30 % to 90 % relative humidity at 40 °C

Safety:

EN61010-1:2013-10

EMC:

EN61000-6-2:2006-10
EN61000-4-4:2013-01
EN61000-6-4:2007-11 + A1:2013-01
EN61000-4-5:2015-05
EN61000-4-2:2011-04
EN61000-4-6:2014-09
EN61000-4-3:2007-04 + A1:2009-01 + A2:2011-01
EN61000-4-11:2006-02

MTBF:

486 years at 35°C ambient temperature

Housing:

Sturdy PBT plastic housing

Protection class:

IP20

Dimensions (WxHxD):

17.5 mm x 100 mm x 112 mm

Connections/mounting:

Pluggable and coded screw terminals up to 2.5 mm2
IDC10 connection for WZ-Bus system on 35 mm top-hat rail
more on request...

 

Weight:

approx. 120 g

Scope of delivery:

Device, installation instructions

Manufacturer:

Seneca s.r.l.

info Signalwandler-Broschüre
Signal converters and monitoring modules

You can download the handout Signal converter here.

Food

Quality control and traceability

sw easy setup
Easy Setup

Configuration software for signal converters.

By downloading and using software and apps from this website, I agree to the GTC and the supplementary software clause.

Vertriebsteam
Für vertriebliche Fragen
Angebot, Produkte, Auftrag und Lieferzeiten
Please contact:
Unseren Vertriebsinnendienst
Für Fragen im Rahmen der Auftragsabwicklung
Auftragsbestätigung, Liefertermin, Rechnung
Please contact:
Unsere Auftragsabwicklung
supportteam
Für technischen Support
im Rahmen der Inbetriebnahme, Projektierung, Konfiguration, etc.
Please contact:
Technischer Support: Mo. bis Do. von 8:00 Uhr bis 16:00 Uhr und Fr. von 8:00 Uhr bis 15:00 Uhr
Article no.Article descriptionAvailablePrice/ItemNumber
WZSG0000

I/O module for DMS

194,00 €
AccessoriesAvailablePrice/ItemNumber
KABUSBM2

USB programming cable, USB 2.0A to micro USB, 2 m cable

9,00 €
WZPCDINAA

Power supply connection terminal, RS485, and bus terminal for 2 modules

33,00 €
WZPCDIN2A

Bus terminal for 2 modules

23,00 €
WZPCDIN8A

Bus terminal for 8 modules

47,00 €
= available from stock
= Delivery time approx. 1 week
= Please inquire about delivery time

Subject to prior sale